SLI-Group Server Center
- Home
- Projects
- Digital city
- SLI-Group Server Center
General information about the project
SLI-Group Server Center
Project name
1000 square meters
Area of the premises
Building a high-performance server center for commercial activities and supporting the digital city
Project goal
625 million rubles
Budget
Main components of the project
Project goals and objectives
Main goal: Developing server infrastructure with high computing power and scalability for business and digital city.
Tasks:
- Placement and configuration of server equipment throughout the entire area of the center.
- Ensuring uninterrupted operation of equipment and security systems.
- Development and implementation of cooling and backup power supply systems.
Main components and specifications
- Number of server racks: 900
- Total number of servers: 5400 servers
- Computing power: up to 2500 kW
- RAM: 691.2 TB
- Data storage (SSD and HDD): 54 petabytes
- Processors (CPU): Multi-core Intel Xeon or AMD EPYC
- Graphics Processing Units (GPUs): For AI and machine learning, NVIDIA Tesla or A100 possible
Work plan and implementation stages
- Design and preparation:
- Analysis of technical requirements and development of an equipment placement plan.
- Preparing the premises: power supply, cooling and ventilation systems.
- Ensuring physical security: video surveillance, access control, fire protection systems.
- Installation and configuration of equipment:
- Purchase and delivery of server racks, servers and network equipment.
- Installation of server racks and placement of servers.
- Setting up and calibrating the cooling and power supply system.
- Integration and testing:
- Integration of servers and network equipment into a single system.
- Testing hardware for performance and stability.
- Optimization and configuration of monitoring and control systems.
- Deployment and Operation:
- Launch of the server center into operation.
- Connection to external networks and integration with client systems.
- Setting up service and technical support processes.
- Control and support:
- Organization of round-the-clock monitoring of the server center status.
- Regular maintenance and updating of equipment.
- Customer support and technical issues resolution.
Technical requirements for the premises
-
- Cooling systems: Liquid cooling and air conditioning.
- Power supply: Backup power supplies (UPS) and diesel generators.
- Physical security: CCTV, access control and fire protection systems.
High-speed network connection: Support 10GbE, 25GbE or 100GbE for high data throughput.
Expected results
- Commercial activities: Allocating 60% of computing power to serving external clients, providing cloud and virtual services.
- Digital City: Using 40% of resources to support smart technologies and manage urban infrastructure.
High availability and fault tolerance: Ensuring uninterrupted operation of the server center with round-the-clock monitoring.
Risks and measures to reduce them
- Equipment Overheating: Implementation of Advanced Liquid Cooling Systems.
- Power Outage: Use UPS and backup generators to maintain uninterrupted operation.
Cyber Threats: Setting up protective measures and security systems to protect data.
Financial planning and budgeting
-
- Equipment purchase: 60% of the budget.
- Infrastructure and cooling systems: 20% of the budget.
- Backup power and security: 10% of budget.
- Installation and integration: 5% of the budget.
- Unforeseen expenses: 5% of the budget.
This project is aimed at creating a high-performance server center that will be used both for commercial purposes and to support the digital city. Thanks to investments in infrastructure and advanced technologies, the SLI-Group server center will become one of the most powerful in the region, providing customers with reliable and efficient IT solutions.